System 
Selection December 16,2007
Guide
Substrate Warranty rate
Benefits Considerations of application
Single-Ply Acry-Tek Bright white, high hide. Clean / Prime with Prep-Tek 500 18 dry mils
(*Fully-adhered only) 5000 Spray, brush or roller apply.  Seasonal Applications (Min.)
EPDM CRRC Listed
Poly-Sil Silicone elastomer Clean / Prime with Prep-Tek 500 18 dry mils
2200 Spray or roller applied Special repair issues (Min.)
Energy Star approved (white)
U.L. Dade Co. CRRC listed
Hypalon / PVC
(No exposed scrim) Poly-Sil    See above
2200
                 * Call technical department for all other
BUR (smooth) Acry-Tek Aliphatic acrylic "bleed-blocker" Two (2) coat system 16 dry mils
& Mod Bit 4000 Spray or roller applied    CRRC listed Seasonal application (Min.)
Coating only
Metal Silver Bullet ™ Hybrid Polyurea Elastomer Need for proper equipment 24 dry mils
  One-coat / Instant set product Prime-Tek 11 primer (Min.)
Used on seams & fasteners Over-spray potential
Labor savings    UL listed
Acry-Tek Bright white / Aliphatic acrylic Caulk seams & fasteners w/ Seal-Tek 800 16 dry mils
9000 Energy Star approved (white) Prime-Tek 7073 for rust (Min.)
Spray or roller applied  D6083, CRRC Apply in multiple coats / must have slope
Seasonal application
Acry-Tek Bright white, high hide. Seal-Tek 800  / Prime-Tek 7073 for rust 18 dry mils
5000 Spray, brush or roller apply.    CRRC Apply in multiple coats.  (Min.)
Seasonal Applications
Urethane Foam Acry-Tek Acrylic elastomer White, Lt. Grey, Dk. Grey  Must have slope 32 dry mils
(New) 4200 CRRC    Energy Star Seasonal application (Min.)
Poly-Sil Silicone elastomer Overspray potential 20 dry mils
2200 Energy Star approved (white) Need for proper equipment (Min.)
U.L, CRRC, Dade Co.
Urethane Foam Acry-Tek Acrylic elastomer White, Lt. Grey, Dk. Grey Must have slope 16 new mils /
(con't) 4200 CRRC       Energy Star Seasonal application Total 32 mils
(Recoat) Prime-Tek 7500 (Min.)
Poly-Sil Silicone elastomer Must recoat w/ silicone 10 new mils /
2200 Energy Star approved (white) Overspray potential Total 20 mils